Menu Close

Vortex Flow Meter

AUD $3,122AUD $14,078

The Vortex flow meter is perfectly suited for measuring the volume of gases and steam using the Karman vortex principle.

Flow Range
1.5 to 300 Nm/sec (5 to 931 ft/sec)

Gas Pressure Range
up to 63 bar (913 psi)

Gas Quality
Wet, dirty compressed air, steam and inert gas systems

Pipe Sizes
DN15 to DN300

Accuracy
Flow: ±1.5% reading, ±0.3% full scale

Output
Modbus (RS485)

Measure
Flow, Pressure, Temperature

Power Requirement
18 to 30VDC / 10W@24V

Bi-directional
No

Measurement Principal
Volumetric

Application
Manufacturing and industrial use
Temporary or permanent installation

Australian dollar ($) - AUD
  • Australian dollar ($) - AUD
  • United States dollar ($) - USD
  • Euro (€) - EUR
  • Canadian dollar ($) - CAD
  • Pound sterling (£) - GBP
  • Singapore dollar ($) - SGD
SKU: FLV Categories: , Tags: ,

The Vortex flow meter is perfectly suited for measuring flow and consumption of inert gases and steam in both clean or dirty gas environments. With no moving parts, these sensors are both durable and easy to maintain.

The design of this meter allows for precise measurements of most gases and steam no matter how heavily contaminated. With built-in pressure and temperature sensors, all parameters of your gas or steam system are monitored in one unit, saving you install and maintenance costs. The integrated display allows installers to set the flow meter without any additional equipment and for users to read the information in real time right at the meter.

Pipe sections are available from DN15 to DN300.

Features of Vortex Flow Meters

  • Inline type sensor
  • Measurement range: 1.5 to 300 Nm/s (5 to 931 ft/sec)
  • Integrated 2” touch screen display
  • Measures flow, pressure, and temperature
  • Ultra-high sensitivity dual vortex probe
  • Turndown ratio of 1:53 goes beyond traditional Vortex flowmeters
  • Full digital signal processing for higher precision and better stability
  • Accuracy of ±1.5% reading, ±0.3% full scale (high accuracy of +/-1% reading, +/-0.3% full scale, available upon request)
  • Integrated pressure and temperature sensors
  • No moving parts
  • Suitable for pipes from DN15 – DN300 provided minimum velocity is maintained
  • Modbus RTU and 4 to 20 mA + Pulse outputs
  • 12 month warranty
  • Full electrical isolation to filter out disturbances
  • Stable signals
  • Vibration resistant
  • All-welded construction for corrosion resistance, high pressure and high temperature resistance

Vortex Flow Meter comes with

  • Calibration certificate
  • User Manual
  • 12 month warranty

Vortex Flow Meter Options

  • Pressure: 1.6 MPa (16 bar) or 6.3 MPa (63 bar)
  • Pipe Section: DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN125, DN150, DN200, DN250, DN300
  • Medium: Gas or Steam
    • Gas Types: Air, Argon, Carbon Dioxide, Carbon Monoxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen

Contact us for other pipe section sizes.

Important

  • Incorrect wiring or installation can give false readings, damage the sensor and void the warranty. If you aren’t sure how to install or wire the sensor, please contact us. Full installation and wiring instructions are available in the User Manual.

Warranty

12 month warranty

Technical Documents

User Manual

Product Flyer

Other Information

Please refer to our Terms and Conditions of Sale.

Specificiations

General

Technology

Vortex, Inline design

Medium

Inert Gas, Steam, Liquids

Gas Types

Air, Argon, Carbon Dioxide, Carbon Monoxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen, Sulfur hexafluoride (SF6)

Accuracy

Flow: ±(1.5% reading + 0.3% full scale)

Note: the accuracy of the sensor is affected by on-site conditions. Contaminants such as oil, high humidity or other impurities can affect the calibration and accuracy of the sensor.

Minimum Gas Flow Required

  • > 1.5 Nm/s
  • > 5 ft/s

Measurement Ranges

Flow Measurement Range

  • 1.5 to 300 Nm/sec
  • 5 to 984 ft/sec

Pressure Measurement Range

  • 0 to 16 bar (1.6MPa, 232 psi)
  • 0 to 63 bar (6.3 MPa , 913 psi)

Temperature Measurement Range

  • Gas: – 40°C to +150°C ( 40°F to +302°F)
  • Steam: -40°C to +280°C ( 40°F to +536°F)

Output

Outputs

Digital: RS485 Modbus / RTU

Modbus Output Signals

  • Flow
  • Pressure
  • Temperature

Power Supply

Power

18 to 30VDC / 10W@24V

EMC

According to IEC 61326-1

Data Logger and Display

Display

2.0” LCD with touch panel

Other Information

Pipe Sizes

DN15 to DN300

Process Connection

Flange

Ambient Temperature Range

  • -40°C to +85°C
  • -40°F to +185°F

Installation Type

Permanent installation, or
Temporary installation

Calibration Frequency

  • Every 2 years (provided the sensor is not exposed to relative humidity above 85%).
  • Annual calibration is required if the sensor is exposed to relative humidity above 85%.

Warranty Period

12 months

Downloads

Installation Manual

Product Flyer