Inline Flow Meter

AUD $1,790AUD $2,576

Inline type, thermal mass flow meter. Flange (DIN) or R-Thread pipe connection. Suitable for pipe sections from DN15 to DN80.

Flow Range
0.1 to 250 Nm/sec (0.3 to 820 ft/sec)

Gas Pressure Range
up to 40 bar (600 psi)

Gas Quality
Clean and dry compressed air and inert gases

Pipe Sizes
DN15 to DN80

Pipe Connection
Flange or R-Thread

Accuracy
Flow: ±1.5% reading, ±0.3% full scale
(high accuracy ±1% reading, ±0.3% full scale available on request)

Output
Modbus (RS485) and 4-20mA

Measure
Flow, Mass Flow, Consumption and Temperature

Power Requirement
18 to 30VDC / 5W@24VDC

Bi-directional
No

Measurement Principal
Mass Flow

Application
Manufacturing and industrial use
Temporary or permanent installation

Accessories
The transparent Flow Meter Enclosure will protect the flow meter head from liquids and other damage
Extra M12 connectors and data cables are available on the Accessories page

Australian dollar ($) - AUD
  • Australian dollar ($) - AUD
  • United States dollar ($) - USD
  • Euro (€) - EUR
  • Canadian dollar ($) - CAD
  • Pound sterling (£) - GBP
  • Singapore dollar ($) - SGD

Thermal mass flow meters are perfectly suited for measuring clean, dry compressed air and inert gases, where accuracy on smaller pipe sizing is important. Compressed Air Alliance offers two types of thermal mass flow meters – inline (or in-line) flow meter and insertion flow meter.

Inline Flow Meters

  • Inline flow sensors include a section of pipe as part of the flow meter. Threaded pipe sections are available from DN15 to DN50. Flange pipe sections are available from DN15 to DN80.
  • Inline flow meters are best suited to permanent installations as you will need to cut out a section of pipe to install the flow meter. You will also need to turn off compressed air while you install the inline flow meter.

Insertion flow meters

  • Insertion flow sensors are inserted into the pipe through a valve. They can be inserted under pressure so you don’t need to turn off your compressed air system during installation.
  • Insertion flow meters are best used for permanent and temporary installations.
  • For information on the Insertion flow meter, refer to the Thermal Mass Flow Meter page.

Both of Compressed Air Alliance’s thermal mass flow meters (inline and insertion style) have a streamlined sensor tip which ensures minimal impact on gas flow while maintaining accuracy over a wide flow range.

Features of Inline Flow Meters

  • Inline type sensor
  • Thermal mass technology, independent of temperature and pressure change
  • Measurement range: 0.1 to 250 Nm/s (820 ft/s)
  • Integrated temperature sensor
  • Accuracy of ±1.5% reading, ±0.3% full scale (high accuracy ±1% available on request)
  • Modbus RTU and 4 to 20 mA + Pulse outputs
  • 2.8″ ultra-wide viewing angle LCD touch screen
  • Data logging with up to 10,000,000 recording points
  • Suitable for pipes from DN15 – DN80 provided minimum velocity is maintained
  • Measures standard flow, mass flow, consumption and temperature
  • 12 month warranty
  • Ultra-wide 1:2500 turndown ratio
  • Full digital signal processing for higher precision and better stability
  • Integrated gas temperature measurement
  • No moving parts, low pressure drop
  • Full electrical isolation to filter out disturbances
  • Stable signals
  • Vibration resistant

Inline Flow Meter comes with:

  • M12 connector (data cable optional)
  • Calibration certificate
  • User Manual
  • 12 month warranty

Inline Flow Meter Options

  • Pressure: 1.6 MPa (16 bar) or 4.0 MPa (40 bar)
  • Pipe Connection: Flange (DIN) or R-Thread
  • Pipe Section: DN15, DN20, DN25, DN32, DN40, DN50, DN65 or DN80
  • Gas Types: Air, Argon, Carbon Dioxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen

Important

The sensor must be installed (i) in dry gas, (ii) at 90° to the pipe and (iii) away from bends, edges, seams, changes in pipe size and other obstructions,
Incorrect wiring or installation can give false readings, damage the sensor and void the warranty. If you aren’t sure how to install or wire the sensor, please contact us. Full installation and wiring instructions are available in the User Manual.

Warranty & Calibration

12 month warranty

Calibration is recommended every 2 years (provided the sensor is not exposed to relative humidity above 85%).
Annual calibration is required if the sensor is exposed to relative humidity above 85%.

Technical Documents

User Manual
Product Flyer

Accessories

Accessories such as mechanical and electrical fittings are available on the Accessories page.

Other Information

Part Numbers for 16 bar flow sensor, R-Thread Connection: FLF110001, FLF120001, FLF130001, FLF140001, FLF150001, FLF160001, FLF110011, FLF120011, FLF130011, FLF140011, FLF150011, FLF160011, FLF111001, FLF121001, FLF131001, FLF141001, FLF151001, FLF161001, FLF111011, FLF121011, FLF131011, FLF141011, FLF151011, FLF161011
Part Numbers for 40 bar flow sensor, R-Thread Connection: FLF210001, FLF220001, FLF230001, FLF240001, FLF250001, FLF260001, FLF210011, FLF220011, FLF230011, FLF240011, FLF250011, FLF260011, FLF211001, FLF221001, FLF231001, FLF241001, FLF251001, FLF261001, FLF211011, FLF221011, FLF231011, FLF241011, FLF251011, FLF261011

Please refer to our Terms and Conditions of Sale.

Weight N/A
Dimensions N/A

Specificiations

General

Technology

Thermal mass, Inline design

Gases

Air, Argon, Carbon Dioxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen

Gas Quality

Clean and dry gases

Accuracy

Flow: ±(1.5% reading + 0.3% full scale)

Note: the accuracy of the sensor is affected by on-site conditions. Contaminants such as oil, high humidity or other impurities can affect the calibration and accuracy of the sensor.

Minimum Gas Flow Required

  • > 0.1 Nm/s
  • > 0.3 ft/s

Measurement Ranges

Flow Measurement Range

  • 0.1 to 250 Nm/sec
  • 0.3 to 820 ft/sec

Pressure Measurement Range

  • 0 to 16 bar (16 MPa, 232 psi)
  • 0 to 40 bar (40 MPa, 600 psi)

Gas Temperature Measurement Range

  • -40°C to +150°C
  • -40°F to +302°F

Output

Outputs

  • Analogue: 4 to 20mA (3 wire)
  • Digital: RS485 Modbus / RTU

Modbus Output Signals

  • Flow
  • Consumption
  • Temperature

Analogue Output Signals

One measurement only

Power Supply

Power

18 to 30VDC / 5W@24VDC

Electrical Connection

2 x 5 pin M12, female

EMC

According to IEC 61326-1

Data Logger and Display

Data Logger

10,000,000 samples

> 20 samples / second

Display

2.8” LCD with touch panel

Other Information

Pipe Sizes

DN15 to DN80

Process Connection

R thread (ISO-7-1)

Flange (DIN), PN16 and PN40)

Ambient Temperature Range

  • -30°C to +70°C
  • -22°F to +172°F

Installation Type

Permanent installation

Calibration Frequency

  • Every 2 years (provided the sensor is not exposed to relative humidity above 85%).
  • Annual calibration is required if the sensor is exposed to relative humidity above 85%.

Warranty Period

12 months

Downloads

Installation Manual

Product Flyer