Menu Close

Power Meter – Din Rail with Display

USD $460USD $556

This three-phase power meter with Modbus/RTU output is simple to install and easy to configure directly through the built in display and can be connected to your data acquisition system for long term monitoring.

Type
3 phase multi-function power meter

Mounting
Din Rail

Measured Voltage 
0~600 VAC

Output
Modbus RS485

Measurements
Voltage, amps, frequency, kilowatts, kilowatt hours, power factor, reactive power, apparent power and harmonics

Accuracy
±0.5%

Display
1.77 inch TFT screen display

Rogowski Coils options
Comes with 3 rogowski coils
Options: 500 amps, 1,000 amps or 3,000 amps

Power requirement
24 VDC, 45- 60 Hz

Application
Manufacturing and industrial use
Temporary or permanent installation
Mains supply and sub metering individual equipment or sub loads

United States dollar ($) - USD
  • Australian dollar ($) - AUD
  • United States dollar ($) - USD
  • Euro (€) - EUR
  • Canadian dollar ($) - CAD
  • Pound sterling (£) - GBP
  • Singapore dollar ($) - SGD
SKU: POM100 Categories: , Tag:

This single or three phase power meter is simple to install and easy to configure via the display. The power meter can be connected to your SCADA via Modbus/RTU thereby giving you a better understanding of your energy use. Monitor your mains power supply, sub loads or individual equipment.

Monitoring power consumption will give you a clear indication of the energy and cost of running your compressed air system. This power meter measures voltage, amps, kilowatts, power factor, kilowatt hours, kilovolt amps and harmonics. It can be installed on mains supply or used for sub metering individual equipment or sub loads.

Installing power meters on compressors is not difficult but should be done by suitably qualified and experienced technicians. Some knowledge of MODBUS communications is required to connect the power meters to your network.

The unit comes with 3 rogowski coils current transducers. Rogowski coils have a large flexible coil and are an excellent solution where a traditional current clamp is too difficult to fit. The coil is shielded against the influence of external magnetic fields and is suitable for high power load analysis. Coils can be fastened by cable ties for permanent installs.

Best suited to

  • 3 phase or single phase measurements
  • Permanent installations
  • DIN Rail mounting

Key features of the Three Phase Power Meter

  • Multi-function meter with display
  • Measure single or three phase power with the same meter
  • DIN rail mounting
  • Modbus/RTU output
  • Easy to install rogowski coil current transducers
  • Measure:
    • Voltage (V), amps (A) and kilowatts (kW) for each phase and total
    • power factor (PF), reactive power (kVar), apparent power (kVa)
    • kilowatt hours (kWh) and electrical system harmonics (THD)
  • 3 rogowski coil current rating options (500A, 1,000 A or 3,000A)
  • Can be installed on mains supply
  • Can be used for sub metering individual equipment or sub load
  • 12 month warranty

Options for the Three Phase Power Meter

  • Rogowski Coil current rating – 500 amps, 1,000 amps or 3,000 amps

Contact us for other Rogowski Coil sizes.

Warranty

12 month warranty

Technical Documents

User Manual

Product Flyer

Other Information

Part Numbers: POM200100, POM200200, POM200300

Please refer to our Terms and Conditions of Sale.

Weight 0.9 kg
Dimensions 19 × 19 × 15 cm

Specifications

General

Type

Multi-function power meter suitable for power analysis, energy metering and tariff meter

Mounting

Din Rail

Poles Description

  • 3PH4W
  • 3PH3W
  • 1PH2W (L-N)
  • 1PH2W (L-L)
  • 1PH3W (L-L-N)

Display

1.77 inch TFT screen display

Accuracy

±0.5%

Outputs

Output

Digital: RS485 Modbus / RTU

Output Signals

Over 220 channels available including:

  • Voltage (V) for each phase and total
  • Amps (A) for each phase and total
  • Kilowatts (kW) for each phase and total
  • Power factor (PF)
  • Reactive Power (kVar)
  • Apparent Power (kVa)
  • Kilowatt hours (kWh)
  • Electrical system harmonics (THD)

Alarm Relay Output

One way electromagnetic relay output.

Contact capacity: 3A 30V DC, 3A 250V AC

Inputs

Input Type

  • External CT (333mV only) or
  • External Rogowski coil

Current – VCT

0.1 to 99,999A

Current – Channel Input Voltage Range

0-900 mVAC peak, 636 mV RMS

Voltage – Channel Input Voltage Range

0~600 VAC Phase Voltage

Voltage – Maximum range

720 VAC Phase Voltage

Digital input

One-way dry contact input, optocoupler isolation (5kVrms)

Power Supply

Power Supply

24 VDC, 45- 60 Hz

Max Power Consumption

3.5 VA

Electrical Connection

Screw terminals

Electromagnetic Compatibility

Meets IEC 61326-1

Other Information

Dimensions

  • 94.5 mm tall x 72.5 mm wide x 66 mm deep
  • 3.7″ tall x 2.85″ wide x 2.6″ deep

Weight = 259 grams

Overvoltage category

CAT III 1000V
It is suitable for distribution systems below 277 / 480vAC

Ambient Temperature Rang

  • -25°C to +60°C
  • -13°F to +140°F

IP Rating

IP20

Installation Type

Permanent installation, or
Temporary installation

Warranty Period

12 months

Downloads

Installation Manual

Product Flyer

User manual for din rail mounted power meter Product flyer for din rail mounted power meter